There are four reasons why the red fault light on the front panel of the BioCharger will turn on.
- One or both fans are inoperable or obstructed from spinning
- If your BioCharger has the red fault light on, it is likely due to one, or perhaps both, of the fans on the back of your BioCharger not spinning. Below is a short video demonstrating this issue and how to clean your fans.
In short, you will need to ensure that there is nothing entangled in your fans and that your fans are free spinning and clear of any obstructions.
If this does not solve your issue the other possibility is the BioCharger is not on a level surface. Make sure the BioCharger is leveled before operation.
- If your BioCharger has the red fault light on, it is likely due to one, or perhaps both, of the fans on the back of your BioCharger not spinning. Below is a short video demonstrating this issue and how to clean your fans.
2. The ambient temperature in the room is greater than 60 degrees Celsius or 140 degrees Fahrenheit.
3. If the BioCharger is tilted greater than 30 degrees the fault light will come on and the BioCharger will not run a recipe.
4. Over current condition where there is excessive current running through the circuit. If this occurs the fault light will come on and the BioCharger will not run a recipe.